Hydronic Floor Heating Panels

A dry panel system only 26 mm thick. No screed, no curing time, and the room is back in use as soon as the floor goes down.

Low enough for any floor

For new homes and renovations. The panels sit straight on the slab or subfloor. Pipe runs in the channels of the base panel, the cover panel clips over it, and your flooring goes on top. New to hydronic heating? Our hydronic heating guide explains how it works, and our cost guide shows what sets the price.

26 mm

  • Cover panel 6 mm
  • Base panel, with 16 mm PE-RT pipe in its channels 20 mm
  • Finished panel height 26 mm

Shown for the B- and C-Panels. The A-Panel is a single 26 mm panel with cover strips that sit flush. A 1.7 mm HOYA Ondol reflective foil goes underneath every panel, and your floor covering sits on top. Compare it with other systems on our floor heating heights page. Sizes and weights for each panel are on the panel technical data page.

Three panels, laid together

All three are 500 × 500 mm and finish at 26 mm, so they combine across one floor with no change in height.

HOYA Ondol A-Panel, a 500 by 500 mm straight-channel dry hydronic heating panel, shown with its channel cover strips lifted above it

A-Panel

Straight channels for the long runs across the open floor.

  • ChannelsStraight
  • Weight11.2 kg/m²
  • Per box8 panels, 2 m²
HOYA Ondol B-Panel, a 500 by 500 mm dry hydronic heating panel with straight and curved channels, shown with its cover panel lifted above it

B-Panel

Straight and curved channels for turns, sides and corners.

  • ChannelsStraight and curved
  • Weight16.68 kg/m²
  • Per box6 panels, 1.5 m²
HOYA Ondol C-Panel, a 500 by 500 mm open-channel dry hydronic heating panel, shown with its cover panel lifted above it

C-Panel

An open layout where pipes run close together, near doors and boilers.

  • ChannelsOpen
  • Weight15.08 kg/m²
  • Per box6 panels, 1.5 m²

Compare the panels

The same on all three: 500 × 500 mm panels, 26 mm finished height and 4 panels per square metre.

SpecificationA PanelB PanelC Panel
Where it is usedStraight runsCurves and straight runsWhere pipes run close together, such as near doors and boilers
Used withAlways used with B panels; C panels as neededCan be used on its ownCan be used on its own
Channel layoutStraightStraight and curvedOpen
Panel size500 × 500 mm500 × 500 mm500 × 500 mm
Base panel thickness26 mm20 mm20 mm
CoverChannel cover strips, 500 × 30 × 8 mm, 3 per panel, supplied with the panelCover panel, 500 × 500 × 6 mm, supplied with the panelCover panel, 500 × 500 × 6 mm, supplied with the panel
Finished thickness26 mm26 mm26 mm
Weight each2.8 kg incl. cover strips4.17 kg incl. cover panel3.77 kg incl. cover panel
Weight per square metre11.2 kg16.68 kg15.08 kg
Panels per square metre444
Panels per box86 incl. cover panels6 incl. cover panels
Coverage per box2 m²1.5 m²1.5 m²
Weight per box22.4 kg25.02 kg22.62 kg
HOYA Ondol A-Panel, a 500 by 500 mm straight-channel dry hydronic heating panel, shown with its channel cover strips lifted above it

Where it goes

  • Used forStraight runs across the open floor
  • ChannelsStraight
  • Used withAlways with B-Panels; C-Panels as needed

How it is made

  • Base panel26 mm
  • Cover3 channel strips, 500 × 30 × 8 mm

Weight and packing

  • Weight per m²11.2 kg
  • Weight each2.8 kg with strips
  • Box8 panels, 2 m², 22.4 kg
HOYA Ondol B-Panel, a 500 by 500 mm dry hydronic heating panel with straight and curved channels, shown with its cover panel lifted above it

Where it goes

  • Used forCurves and straight runs
  • ChannelsStraight and curved
  • Used withCan be used on its own

How it is made

  • Base panel20 mm
  • CoverCover panel, 500 × 500 × 6 mm

Weight and packing

  • Weight per m²16.68 kg
  • Weight each4.17 kg with cover panel
  • Box6 panels, 1.5 m², 25.02 kg
HOYA Ondol C-Panel, a 500 by 500 mm open-channel dry hydronic heating panel, shown with its cover panel lifted above it

Where it goes

  • Used forWhere pipes run close together, such as near doors and boilers
  • ChannelsOpen
  • Used withCan be used on its own

How it is made

  • Base panel20 mm
  • CoverCover panel, 500 × 500 × 6 mm

Weight and packing

  • Weight per m²15.08 kg
  • Weight each3.77 kg with cover panel
  • Box6 panels, 1.5 m², 22.62 kg

Covers are supplied in the box with each panel.

Dry panel or wet screed?

Most hydronic floors are pipe set in a concrete screed. A dry panel does the same job without the depth, the weight or the wait.

HOYA Ondol dry panel

  • Height26 mm
  • Weight11.2 to 16.68 kg/m²
  • LayingLay the base panels, press in the pipe, fit the covers
  • Later changesPanels lift out and can be reused

Wet screed

  • HeightAbout 70–110 mm, including the insulation board
  • WeightAbout 120 kg/m²
  • LayingLay insulation and pipe, pour the screed, then wait for it to cure
  • Later changesConcrete has to be broken out

How a floor goes in

HOYA Ondol dry panels laid across a room before the pipe goes in

1Lay the base panels

Reflective foil first, then the base panels clip together across the room.

Installers pressing heating pipe into HOYA Ondol panels

2Press in the pipe

16 mm PE-RT pipe is pressed into the channels, following the layout plan.

Cover panels going down over the heating pipe in HOYA Ondol panels

3Cover and finish

Covers go on, then timber, laminate or vinyl goes straight over. Tiles go on a 6 mm tile board.

The panels can be laid by a builder, carpenter or flooring installer, following HOYA Ondol’s installation instructions and the panel and pipe layout designed for your floor, working with your hydronic installer. Manifold, heat pump or boiler connections must be made by a licensed plumber, and electrical work by a licensed electrician. In some states, laying the heating pipe itself is also licensed plumbing work, so check with your installer. Warranty requires licensed connections. This does not limit your rights under the Australian Consumer Law.

Rooms it suits

Bright open living room with light timber floors and white furniture

Living areas

Even warmth across open-plan rooms.

Bedroom with a timber floor and a made bed beside a sash window

Bedrooms

Quiet heat with no draughts or fan noise.

Modern bathroom with a freestanding bath and large grey floor tiles

Bathrooms

Warm tiles underfoot.

Open-plan kitchen and dining area with a tiled floor and island bench

Kitchen and dining

Works under tiles and hard floors.

What else the system needs

We quote the full kit for your floor plan, not just the panels.

Reflective foil

A 1.7 mm foil that goes under the panels to send heat upwards.

Edge strips

Finish the panel edges along walls, where your floor needs them.

16 mm PE-RT pipe

Runs in the panel channels.

Manifold

Splits flow to each heating circuit.

Room thermostats

Set each zone to its own temperature.

Heat source

A heat pump or boiler heats the water.

Planning a heated floor?

Send us your floor plan and we’ll quote the panels, pipe and manifold for your rooms.