HOYA Ondol floor heating system

HOYA Ondol Reflective Foil

Dry hydronic floor heating with a 27.7 mm build-up, foil and panel together. Made in Gunsan, South Korea, and delivered Australia-wide from our Carrum Downs warehouse in Victoria.

The 1.7 mm reflective foil that goes under every HOYA Ondol panel. Rolls are 25 m × 1 m, covering 25 m² each, and come with foil tape for the joins.

  • Delivered Australia-wide from our Carrum Downs warehouse in Victoria.
  • Every floor gets its own panel and pipe layout, designed by HOYA Ondol.
  • Questions? Call 1300 137 407.

The panels can be laid by a builder, carpenter or flooring installer. Manifold, heat pump or boiler connections must be made by a licensed plumber, and electrical work by a licensed electrician. Warranty requires licensed connections. This does not limit your rights under the Australian Consumer Law.

Description

HOYA Ondol reflective foil is the first layer of every HOYA Ondol floor. It is rolled out over the clean, level floor before the panels go down, and it sends heat from the pipe upwards into the room. See how the panels are laid.

  • Construction: reflective foil on both faces, with a fibre matting core. There is no bubble layer.
  • Roll size: 25 m × 1 m, 1.7 mm thick, covering 25 m² per roll.
  • Build-up: 1.7 mm foil plus the 26 mm panel gives 27.7 mm before the floor finish. See how much height floor heating adds.
  • Taped joins: the joins are taped with HOYA Ondol foil tape, which comes with each roll, so the layer stays flat and continuous.
  • Over existing tiles: tiles can stay. The foil goes over them, then the panels.
  • Floor preparation: the floor needs to be within 3 mm over 1 m. More than that may need patching or a self-levelling compound first.
  • Used with: A-Panels, B-Panels and C-Panels.

We work out how many rolls your floor needs as part of your layout and quote.

Additional information

Dimensions 25000 × 1000 × 1.7 mm
Construction

Double-sided reflective foil with a fibre matting core (no bubble layer)

Thickness

1.7 mm

Roll size

25 m × 1 m

Coverage per roll

25 m²

Build-up with panel

27.7 mm (1.7 mm foil + 26 mm panel), before the floor finish

Joins

Taped with HOYA Ondol foil tape

Foil tape supplied

Yes, with each roll

Used with

HOYA Ondol A-, B- and C-Panels

Installation

The panels can be laid by a builder, carpenter or flooring installer, following HOYA Ondol’s installation instructions and the panel and pipe layout designed for your floor. Manifold, heat pump or boiler connections must be made by a licensed plumber, and electrical work by a licensed electrician. In some states, laying the heating pipe itself is also licensed plumbing work, so check with your installer. Warranty requires licensed connections. This does not limit your rights under the Australian Consumer Law.