Independent research on floor heating

What published studies say about warm-up time, comfort and energy use for heavy and light heated floors, summarised in plain English.

How to read these studies

Each summary says what the researchers tested, what they found and what it means for a HOYA Ondol floor. The summaries are ours, and the links go to the original papers. None of these studies tested HOYA Ondol panels, so read them for the principles, not as a promise for your home.

The studies

Seven studies from Europe, North America and South Korea, and what we take from them.

REHVA Journal · 2018 · Simulation

Comparative performance analysis of floor heating systems

What it tested: Gritzki, Naumann and Kandzia modelled a 9 m² test room with a standard 65 mm wet screed and three thinner renovation systems, including a dry system, all starting from cold with 35 °C water.

What it found: The thin dry system reached the target floor temperature three times faster than the 65 mm screed. Under a timber parquet floor every system was slower and the differences were smaller.

What it means for HOYA Ondol: Supports the point that a floor with less mass warms up sooner. It did not test HOYA Ondol panels.

Buildings (MDPI) · 2024 · Two-room test

Experimental and numerical study of a lightweight radiant floor heating system

What it tested: Zhang, Wang, Liu and Zhang heated two identical rooms, one with a prefabricated dry floor and one with a conventional concrete-filled floor, using the same water supply.

What it found: The dry floor surface settled in about 120 minutes against about 180 minutes. After the heating stopped, the dry-floor room cooled below 16 °C in about 40 minutes against about 80 minutes.

What it means for HOYA Ondol: A measured result showing a dry floor responds faster in both directions. It did not test HOYA Ondol panels.

SSRN preprint · 2026 · Full-scale test cells

Screed thickness effects on thermal response and energy use

What it tested: Kim, Shim, Yoon and Song at Sungkyunkwan University, South Korea, ran two identical test rooms for 17 days, one with a 40 mm screed over the pipes and one with 70 mm.

What it found: From cold, the 70 mm screed took 47.1% longer (250 against 170 minutes) and used 48.3% more energy (17.5 against 11.8 kWh) to bring the room to 19 °C, and about 6.1% more energy over the whole test. This preprint has not yet been peer reviewed.

What it means for HOYA Ondol: Shows that the extra mass over the pipe costs time and energy at start-up. HOYA Ondol has no screed to heat, but this study compared two screeds, not a dry panel.

ASHRAE Journal · 2020 · Modelled houses

Using radiant floor heating systems for efficient residential heating

What it tested: Brideau, Beausoleil-Morrison and Kummert modelled houses with radiant floors of different mass, different amounts of sunny glazing and different controllers.

What it found: With typical glazing, the lightest floor used up to 8% less energy than heavier floors. With large areas of sunny glazing, heavier floors gave up to 7% better comfort. The choice of controller made a 25% difference to heating energy.

What it means for HOYA Ondol: Good controls matter as much as the floor. Room thermostats and a well-set heat pump are part of every HOYA Ondol quote.

Applied Sciences (MDPI) · 2018 · Simulation

Efficiency of low-temperature radiant systems under dynamic conditions

What it tested: Alessio, De Carli, Zarrella and Di Bella at the University of Padua modelled wet screed floors, dry floors and radiant ceilings in several kinds of building.

What it found: In uninsulated and insulated buildings the dry floor was about 93% efficient against about 96% for the wet floor. In well-insulated light buildings all systems were 98–99%. The authors found no evidence that dry floors are more efficient than wet screed.

What it means for HOYA Ondol: An honest counterpoint: the case for a dry panel is speed, height and weight, not lower energy use in every house.

ASHRAE Transactions · 1998 · Field surveys, 160 buildings

Developing an adaptive model of thermal comfort and preference

What it tested: Richard de Dear (now at the University of Sydney) and Gail Brager pooled about 21,000 comfort surveys from 160 buildings around the world, and compared how people felt with the indoor and outdoor temperatures at the time.

What it found: People’s preferred indoor temperature moved with the climate and the season. People in naturally ventilated buildings were comfortable across a much wider range than a fixed setpoint allows. This work led to the adaptive comfort model in the international comfort standard ASHRAE 55.

What it means for HOYA Ondol: There is no single “right” setting such as 22 °C. The comfort standards also count the temperature of the surfaces around you, not only the air. A warm floor raises that surface temperature, which is part of why a heated floor can feel comfortable at a lower thermostat setting. This study did not test floor heating or HOYA Ondol panels.

Chinese Science Bulletin · 2021 · Human trial, 45 people

Comfortable floor temperatures for radiant floor heating

What it tested: Wu, Liu, Li, Lu, Chen and Kosonen had 45 adults sit barefoot for two hours in a heated home in Chongqing, at six floor surface temperatures from 25 to 35 °C.

What it found: For long stays, people felt neutral with the floor at about 28 °C, and most preferred about 32 °C. The room air stayed between about 19 and 23 °C across the tests. The authors recommend designing frequently used rooms for a floor surface of 25 to 29 °C, with 32 °C as the upper limit. ISO 7730 and ASHRAE 55 give 19 to 29 °C for people wearing light shoes.

What it means for HOYA Ondol: Bare feet like a warmer floor than the standards’ upper limit, but living areas are still designed within it. Your installer designs each floor’s surface temperature from your plans. This study did not test HOYA Ondol panels.

Our reading · Summary

What the research tells us

Faster response: Two independent studies found low-mass floors warm up and respond faster than screed or slab. That is the main benefit for a home heated when it is used.

Energy use depends on the house: The evidence on energy savings is mixed. Insulation, glazing and how you run the system matter more than the floor type alone.

Controls make the difference: One study found the controller changed heating energy by 25%. Zoning room by room and a well-set heat pump are where the savings come from.

Comfort is more than the air temperature: The comfort standards count the temperature of the surfaces around you as well as the air. A warm floor raises that surface temperature, so many people feel comfortable with the thermostat set lower. Floor surfaces are designed to stay within the comfortable range, which the standards put at 19 to 29 °C.

Keep reading

More on choosing a floor heating system.

HOYA Ondol · Web page

Hydronic heating guide

How hydronic floor heating works, what it costs and the trade-offs.

HOYA Ondol · Web page

Resources and downloads

Brochures, data sheets, installation guides and manuals.

Installation and warranty

The panels can be laid by a builder, carpenter or flooring installer, following HOYA Ondol’s installation instructions and the panel and pipe layout designed for your floor, working with your hydronic installer. Manifold, heat pump or boiler connections must be made by a licensed plumber, and electrical work by a licensed electrician. In some states, laying the heating pipe itself is also licensed plumbing work, so check with your installer. Warranty requires licensed connections. This does not limit your rights under the Australian Consumer Law.

Questions about the research?

Tell us about your home and we’ll explain what it means for your floor.