Hydronic underfloor heating: your questions answered

Straight answers about HOYA Ondol dry-panel hydronic floor heating: how much height it adds, which floors and heat sources it suits, who can install it, what it costs, and its downsides. Each answer links to the page with more detail, and unfamiliar terms are explained in the hydronic heating glossary.

Last updated 6 October 2026.

The basics

What is hydronic underfloor heating?

Hydronic underfloor heating warms a room through the floor. Warm water from a heat pump or boiler runs through pipe under the floor finish, the floor warms up, and it gives off gentle, even heat across the room. With HOYA Ondol, the pipe sits in 26 mm panels laid on top of the slab or subfloor.

How is a dry-panel system different from in-slab or in-screed heating?

In-slab heating has the pipe cast into a new concrete slab, so it only suits new builds. In-screed heating sets the pipe in a layer of sand-cement screed, which adds roughly 70–110 mm above the slab and has to dry before the floor finish goes down. A dry-panel system like HOYA Ondol presses the pipe into channels moulded into the panels, so nothing is poured and the floor finish can go down once the pipe has been pressure tested. Compare the height each system adds.

Is electric or hydronic underfloor heating better?

Electric underfloor heating uses heating cables or mats under the floor finish. It is cheap to put in and suits a bathroom or a single small room, but every unit of heat comes straight from electricity, so it is expensive to run over large areas. Hydronic heating circulates warm water from a heat pump or boiler. It costs more to put in, but a heat pump makes several units of heat for each unit of electricity it uses, so it is usually much cheaper to run across a whole house. The heat source can also be changed later without lifting the floor.

What are the A, B and C panels for?

All three panels are 500 × 500 mm and finish at 26 mm, so they sit flush across one floor. The A-Panel has straight channels for long runs across open floor. The B-Panel has straight and curved channels for turns, sides and corners. The C-Panel has an open layout for where pipes run close together, near doors and the manifold. We design the mix of panels for your floor plan. See the panels.

What does "ondol" mean?

Ondol is the Korean word for a heated floor. HOYA Ondol is the name of this hydronic dry-panel system, made in Korea by Hoya Hometech.

Floor height and floor finishes

How much height does HOYA Ondol add to my floor?

27.7 mm before the floor finish: a 1.7 mm HOYA Ondol reflective foil and the 26 mm panel. Tiles need a 6 mm tile board on top. With 14.2 mm engineered floating timber, the finished floor sits 41.9 mm above the slab, plus any underlay. See the build-up heights for each system.

Can floor heating go over my existing floor?

Yes. HOYA Ondol panels are laid on a sound, level concrete slab or subfloor, so a renovation needs no new slab or screed. In Daylesford the panels went on reflective foil straight over the old concrete floor. In O’Connor they went over the particleboard subfloor. Check door clearances, thresholds and where the new floor meets other rooms before you start.

How flat does my floor need to be?

Within 3 mm over 1 m. If the floor varies by more than 3 mm, it may need patching or a coat of self-levelling compound before the foil and panels go down.

Can the panels go over existing tiles?

Yes, the tiles can stay. The reflective foil goes straight down over the existing tiles and the panels are laid on the foil. As with any floor, the tiles need to be within 3 mm over 1 m. If they are out by more than that, the floor may need patching or a coat of self-levelling compound first.

What flooring is best for hydronic underfloor heating?

Most finishes work if their maker approves them for floor heating. Thinner, denser finishes such as tiles and stone pass heat most readily. Over HOYA Ondol you can use engineered timber floated over the panels, tiles on a 6 mm tile board, hybrid, SPC or stone laid to their maker’s floor heating requirements, and carpet on a carpet underlay laid straight over the panels.

Can timber flooring be glued to the panels?

No. Engineered timber is floated over the panels and never glued to them. Choose a timber floor its maker approves for use over floor heating, and follow the maker’s limits on floor temperature.

Can I have carpet over floor heating?

Yes. The carpet underlay goes straight onto the panels, with the carpet on top, so the height is 27.7 mm plus the underlay and carpet. Nothing is nailed into the panels, so ask us how the gripper strips at the edges are fixed before you start.

Heat source and controls

What heats the water?

A heat pump or a boiler, sized by your hydronic installer for the area you heat. We can supply air-to-water heat pumps with the system. See the heat pumps.

Can I heat some rooms and not others?

Yes. The pipe circuits run room by room from the manifold, so each room or area can be its own zone with its own thermostat. Heating only the rooms you use, when you use them, keeps running costs down.

What does floor heating cost to run?

It depends on the heat source, your energy tariff, how well the house is insulated, and how many rooms and hours you heat. A heat pump gives several units of heat for each unit of electricity it uses, which is why it is the usual choice. We can’t give a running cost without your plans and how you plan to heat the house.

Cost and buying

How much does hydronic underfloor heating cost?

It depends on the area, the rooms and the heat source, so we price each job from its plans. Send us your plans for a panel and pipe layout and a full system quote. Our cost guide explains what sets the price.

What do I get with a quote?

A panel and pipe layout designed for your floor plan, and a price for the full system, from the panels and pipe to the heat source and controls.

Do you supply my area?

We are based in Mount Gambier, South Australia, and supply HOYA Ondol Australia-wide.

How long does installation take?

It depends on the job: a single room is much quicker than a large house, and the heat source makes a difference too, whether it is a heat pump or an electric boiler. Because nothing is poured, there is no drying time. The floor finish can go down once the pipe has been pressure tested. We can give you an idea of timing with your layout and quote.

Installation and warranty

Can I install HOYA Ondol myself?

Not all of it. The panels can be laid by a builder, carpenter or flooring installer, following our installation instructions and the panel and pipe layout designed for your floor, working with your hydronic installer. Manifold, heat pump or boiler connections must be made by a licensed plumber, and electrical work by a licensed electrician. In some states, laying the heating pipe itself is also licensed plumbing work, so check with your installer. Warranty requires licensed connections.

What warranty comes with HOYA Ondol?

The panels have a warranty from HOYA Ondol Australia, and its length is set out on your quote. The 16 mm PE-RT pipe is covered by its maker’s warranty. Licensed connections are a condition of the warranty, and you register your system once it is installed. Read the warranty conditions. Nothing in the warranty limits your rights under the Australian Consumer Law.

Can HOYA Ondol be used in apartments or commercial buildings?

Not at this stage. HOYA Ondol is supplied for houses (NCC Class 1) only.

Downsides and trade-offs

What are the downsides of hydronic floor heating?

It usually costs more to put in than a split-system air conditioner. It heats but does not cool. It changes temperature more slowly than blown air, so it suits steady heating or a timer rather than quick bursts. Any system laid on top of the floor raises it, and the connections need licensed trades. Our hydronic heating guide covers the trade-offs in more detail.

What are the downsides of HOYA Ondol?

It adds 27.7 mm before the floor finish, which is more than a self-levelling low-profile system at about 15–17 mm plus flooring. It also uses more pipe per square metre than wide-spaced panel systems. In return, nothing is poured or left to dry, the panels weigh 11.2–16.68 kg/m² against about 120 kg/m² for wet screed, and the 16 mm PE-RT pipe at 169 mm spacing needs fewer circuits than a low-profile system for the same floor.

What are common problems with underfloor heating?

The usual complaints are slow warm-up, uneven heat, high running costs and, with pipe cast into a slab or screed, leaks that are hard to reach. Most come down to design and setup: a heat source that is too small or runs too hot, pipe circuits that are too long, or a floor finish that holds the heat in. With HOYA Ondol, each circuit is one continuous loop of pipe from the manifold and back, with no joints under the floor. Engineered timber floors also need a gradual heat-up before they are laid and a floor surface no hotter than 27°C, or the boards can gap and cup.

Still have a question?

Send us your plans and we’ll reply with a panel and pipe layout and a full system quote, or call us to talk it through.

Where to next

HOYA Ondol B-Panel, a 500 by 500 mm dry hydronic heating panel with straight and curved channels, shown with its cover panel lifted above it

HOYA Ondol panels

A, B and C panels for timber, tile and renovation floors.

Timber frame of a new two-storey house under construction

Send us your plans

A heating layout and quote prepared from your house plans.

Illustration of two miniature installer figures in orange high-visibility vests standing on a black HOYA Ondol floor heating panel, one checking a tablet and one pointing at the white heating pipe in its channel

Support

Installation guides, panel specifications and videos.

Renovated room with newly finished timber floorboards and a floor vent

Register your warranty

Record your installation and the licensed trades who did it.