HOYA Ondol panel technical data

Sizes, weights, build-up, pipe layout and materials for the A, B and C panels, and who makes them.

Panel specifications

All three panels are 500 × 500 mm and finish at 26 mm, so they combine across one floor with no change in height. Four panels make one square metre.

A-Panel

Straight channels for long runs across open floor.

  • Panel size500 × 500 mm
  • Base panel26 mm
  • Cover3 strips, 500 × 30 × 8 mm
  • Finished height26 mm
  • Weight11.2 kg/m²
  • Box8 panels, 2 m², 22.4 kg

B-Panel

Straight and curved channels for turns, sides and corners.

  • Panel size500 × 500 mm
  • Base panel20 mm
  • CoverCover panel, 6 mm
  • Finished height26 mm
  • Weight16.68 kg/m²
  • Box6 panels, 1.5 m², 25.02 kg

C-Panel

Open layout where pipes run close together, near doors and the manifold.

  • Panel size500 × 500 mm
  • Base panel20 mm
  • CoverCover panel, 6 mm
  • Finished height26 mm
  • Weight15.08 kg/m²
  • Box6 panels, 1.5 m², 22.62 kg

Build-up

A 1.7 mm HOYA Ondol reflective foil goes under every panel, so the heating layer is 27.7 mm before the floor finish.

  • Reflective foil1.7 mm
  • Panel, finished26 mm
  • Heating layer27.7 mm
  • With 14.2 mm floating timber41.9 mm, plus any underlay
  • TilesOn a 6 mm tile board
  • Floor flatnessWithin 3 mm over 1 m

Compare it with other systems on how much height floor heating adds. Terms such as build-up, flow temperature and PE-RT are explained in the hydronic heating glossary.

Labelled exploded view of a HOYA Ondol A panel floor on a concrete slab. From the bottom: existing slab, 1.7 mm reflective foil, 26 mm A panel with 16 mm PE-RT pipe in its straight channels, cover strips (shown lifted), then 14.2 mm engineered floating timber. Heating layer 27.7 mm; finished height 41.9 mm over the slab, plus any underlay.
PE-RT heating pipe being pressed into the channels of a HOYA Ondol B-Panel

Pipe and layout

The pipe presses into the channels of the base panel and the cover goes over the top. Every circuit is designed from your plans.

  • Pipe16 mm PE-RT, 2.0 mm wall
  • Oxygen barrierYes, to DIN 4726
  • Pipe spacing169 mm centres
  • Longest circuit90–95 m
  • Joints under the floorNone
  • Manifold2 to 12 circuits

More on the pipe and manifolds.

Material, maker and documents

What the panels are made of

All three HOYA Ondol panels are made from the same material: a mix of graphite, volcanic rock and other natural materials. Graphite conducts heat well, so warmth from the pipe spreads evenly across the panel and into your floor, where it is released as gentle radiant heat.

Who makes HOYA Ondol

HOYA Ondol panels are made by Hoya Hometech Co., Ltd at its factories in Gunsan, South Korea.

Installation and warranty

The panels can be laid by a builder, carpenter or flooring installer, following HOYA Ondol’s installation instructions and the panel and pipe layout designed for your floor, working with your hydronic installer. Manifold, heat pump or boiler connections must be made by a licensed plumber, and electrical work by a licensed electrician. In some states, laying the heating pipe itself is also licensed plumbing work, so check with your installer. Warranty requires licensed connections. This does not limit your rights under the Australian Consumer Law.

Need more detail?

Builders, designers and plumbers: call or send your question and plans, and we’ll come back with the figures for your job.