Floor Heating Pipe and Manifolds

The pipe and manifold carry warm water from your heat pump to every room. With HOYA Ondol, the pipe sits in 26 mm dry panels instead of a slab or screed, and every circuit is designed from your plans.

  1. Flow meter on every circuit
  2. Valve for a room thermostat
  3. Flow and return thermometers
  4. Isolating ball valves
  • 16 mmPE-RT pipe
  • 169 mmpipe centres
  • 2 to 12circuits per manifold
Floor heating manifold with four circuits: flow meters, room valves, thermometers and isolating ball valves

How the water gets to your floor

A hydronic floor is a closed loop: the same water goes round and round.

1The heat source warms the water

A heat pump or boiler heats the water, usually to 35–45 °C for a timber floor.

2The manifold splits the flow

One manifold feeds a separate pipe circuit for each room or area, with a flow meter on every circuit.

3The pipe runs through the panels

Each circuit loops through the HOYA Ondol panels at 169 mm centres and warms the floor above.

4The water returns to be reheated

Cooled water comes back through the manifold to the heat source.

The heating pipe

HOYA Ondol uses 16 mm PE-RT floor-heating pipe with an oxygen barrier. The pipe presses into the channels in the HOYA Ondol base panels, and the cover panels go over the top.

Each circuit is laid as one length of pipe from the manifold and back, so there are no joints under the floor. We design every circuit from your plans: which rooms it serves, its route through the panels and its length.

  • Pipe16 mm PE-RT, 2.0 mm wall
  • Oxygen barrierYes, to DIN 4726
  • Pipe spacing169 mm centres
  • Longest circuit90–95 m
  • Joints under the floorNone
Two installers in hi-vis vests checking a pipe layout on a tablet beside floor heating panels with white pipe

Why the oxygen barrier matters: heat pump makers require it. Without one, oxygen can pass through the pipe wall into the water and corrode metal parts in the heat pump and pumps.

Two black plastic manifold bars: one with six white valve caps and one with six red flow meters

The manifold

We supply the Uponor Vario PLUS, a modular plastic manifold. It comes assembled for 2 to 12 circuits, with a flow meter on every circuit so your plumber can balance the flow to each room.

The return valves take thermal actuators, so each room or zone can be switched by its own thermostat.

  • MakeUponor Vario PLUS
  • Circuits2 to 12
  • BodyGlass-fibre reinforced polyamide
  • On each circuitFlow meter and actuator valve
  • Supplied withThermometers, ball valves, brackets and air bleeders
  • ConnectionsG 1″ mains, G ¾″ Eurocone circuits
  • RatingUp to 60 °C and 6 bar
  • Maximum flow1 L/s per manifold
  • Actuators24 V or 230 V

Figures from Uponor’s Vario PLUS product data and installation manual. HOYA floors run well below the 60 °C limit.

Pipe in panels, not in a slab or screed

The two other common ways to get hydronic heat into a floor, and what each one costs you.

Cutaway of a concrete slab with white heating pipe tied to the steel reinforcement mesh in a serpentine layout. Part of the slab is cut back to show the pipe cast into the concrete.

Alternative 1

In-slab heating

The pipe is tied to the reinforcing mesh before the concrete slab is poured.

What it costs you

  • Only possible before the slab is poured, so new builds only
  • The whole slab has to warm up, so it is slow to respond and usually runs all the time
  • A damaged pipe in the concrete is very hard to reach
Cutaway of an in-screed floor: a concrete slab, a black studded insulation board holding white heating pipe in a serpentine layout, and a sand and cement screed poured over the top, cut back to show the pipe.

Alternative 2

In-screed heating

The pipe is laid over the slab and covered with a poured sand-cement or flowing screed.

What it costs you

  • Adds about 70–110 mm to the floor height, which raises doors, steps and thresholds in a renovation
  • Adds about 120 kg/m² to the floor
  • Weeks of drying before the floor covering goes down

Material the heating has to warm

  • HOYA Ondol panels under 17 kg/m²
  • Heating screed about 120 kg/m²
  • 100 mm concrete slab about 240 kg/m²

Typical figures per m², not measurements from a particular job. The panel figure is the whole HOYA Ondol panel; the slab figure assumes about 2,400 kg/m³ concrete.

Why it matters

Less mass, faster response

Heat has to warm everything above and around the pipe before the room feels it. A slab or screed stores a lot of heat, so it takes longer to warm up and keeps heating after you turn it down. HOYA Ondol panels have far less to warm, so the floor follows the thermostat more closely.

HOYA Ondol adds 27.7 mm including the foil underlay, with nothing to pour or dry. It suits new builds and existing homes, and the floor covering can go down once the pipe is pressure-tested and, for timber, the heating is commissioned. See how much height floor heating adds.

Testing and commissioning

Done by a licensed plumber before anyone walks on the finished floor. The full sequence is in our guide to installing HOYA Ondol panels.

1Pressure test

Before the cover panels and floor covering go down, the plumber fills the circuits and pressure-tests them to the manifold maker’s procedure.

2Fill and purge

Each circuit is flushed and the air bled out at the manifold.

3Balance the flow

The flow meters are set so each room gets the flow its design calls for.

4Commission the heating

The system is started and checked. Under engineered timber, the heating is brought up gradually before the boards are laid.

Pipe and manifold questions

16 mm PE-RT floor-heating pipe with an oxygen barrier to DIN 4726, laid at 169 mm centres in the panels.

We design circuits up to 90–95 m. Larger rooms get more than one circuit.

No. Each circuit is one length of pipe from the manifold and back. The only joints are at the manifold.

A Vario PLUS manifold takes 2 to 12 circuits. Bigger homes can have more than one manifold.

Yes. Each circuit has a valve that takes a thermal actuator, switched by a room thermostat.

Usually in a cupboard or wall cabinet central to the rooms it serves, where the plumber can reach it.

Installation and warranty

The panels can be laid by a builder, carpenter or flooring installer, following HOYA Ondol’s installation instructions and the panel and pipe layout designed for your floor, working with your hydronic installer. Manifold, heat pump or boiler connections must be made by a licensed plumber, and electrical work by a licensed electrician. In some states, laying the heating pipe itself is also licensed plumbing work, so check with your installer. Warranty requires licensed connections. This does not limit your rights under the Australian Consumer Law.

Get a pipe and manifold layout

Send us your plans. We’ll design the panel layout, the pipe circuits and the manifold, and quote the system together with a heat pump if you need one.