Hydronic heating: a plain-English guide

How hydronic heating works, radiators or underfloor, what it costs to run, the downsides and whether it suits your home. Written for Australian homeowners who are building, renovating or replacing old heating.

What is hydronic heating?

Hydronic heating warms your home with water instead of air. It has three parts. Unfamiliar terms are explained in the hydronic heating glossary.

The heat source

A gas boiler or an air-to-water heat pump heats water, usually outside or in a laundry or garage. The water stays in a sealed loop and is used again and again.

Pipes and a manifold

The warm water is pumped through pipes to a manifold, which sends it to each room and lets a thermostat in each room turn its loop on and off.

Radiators or the floor

The heat comes into the room through wall radiators, or through pipes laid in the floor so the whole floor becomes a gentle, even heater. No air is blown around the room.

Radiators or underfloor heating?

Both use the same heat source and pipes. The difference is how the heat gets into the room. To weigh hydronic heating against blown air, see hydronic vs ducted vs split-system heating.

Radiators and panel heaters

  • Quick to warm a room, and easy to add room by room in an existing house
  • Needs hotter water than underfloor heating, which suits gas boilers better than heat pumps
  • Takes up wall space and furniture has to be kept clear of it
  • Heat rises from each radiator, so rooms can be warmer near the ceiling

Underfloor heating

  • The whole floor gives off gentle heat, so the room is even from floor to head height
  • Works at lower water temperatures, which suits an air-to-water heat pump
  • Nothing on the walls, so every wall is free for furniture
  • Has to go in when the floor is being built or replaced, and the floor covering must suit it

Three ways to put hydronic heating in a floor

The pipes can go in the concrete, in a screed over the concrete, or in dry panels. Which one fits depends on whether you are building new or working with an existing floor.

Cutaway of a concrete slab with white heating pipe tied to the steel reinforcement mesh in a serpentine layout. Part of the slab is cut back to show the pipe cast into the concrete.

In the slab

Pipes are tied to the steel mesh before a new concrete slab is poured. It suits new homes on a slab. The slab holds a lot of heat, so it is slow to warm up and slow to cool down, and it is usually left running through winter.

Cutaway of an in-screed floor: a concrete slab, a black studded insulation board holding white heating pipe in a serpentine layout, and a sand and cement screed poured over the top, cut back to show the pipe.

In a screed

Pipes are laid on insulation and covered with a sand and cement screed several centimetres thick. It adds height and weight, and the screed must dry before the floor covering goes down.

What heats the water?

The heat source sets most of your running cost, so it is worth choosing it together with the radiators or floor.

Gas boiler

The traditional choice. A boiler heats water quickly to the higher temperatures radiators need. Running costs follow gas prices, and some households are moving away from gas.

Electric boiler

A compact electric boiler heats the water with an element. There is no outdoor unit and it costs less to install, but like any resistance heater it gives 1 kWh of heat for each kWh of electricity, so it costs more to run than a heat pump.

Air-to-water heat pump

A heat pump takes heat from the outside air and puts it into the water, using electricity to move heat rather than make it. It runs most efficiently at the low water temperatures underfloor heating needs, and can run on solar power during the day.

Heat out for each unit of energy in: air-to-water heat pump about 3.5 (the HydroAir Next Gen we supply is rated at a COP of 3.55), gas boiler about 0.9, electric boiler or electric heaters 1.0.

How hydronic floor heating is installed

The order of work is much the same for every floor. What changes is how the pipe is held in place and what covers it.

1. Plan the system

Each room’s heat loss is worked out from its size, insulation and windows. That sets the pipe in each room, how the loops are split and the size of the heat source. We draw the panel and pipe layout from your floor plan, and mark where the manifold and heat source go.

2. Prepare the floor

In a slab, insulation goes under and around the edge before the steel mesh. For a screed, insulation boards and an edge strip go down on the slab. For dry panels, the floor must be clean, level and sound, and HOYA Ondol reflective foil goes down first.

3. Lay the pipe

In a slab the pipe is tied to the mesh, and in a screed it is clipped to the insulation. In dry panels it presses into the grooves: HOYA Ondol takes 16 mm PE-RT pipe at 169 mm centres. Each loop runs from the manifold and back as one length, so there are no joints under the floor.

4. Pressure test

Before anything covers the pipe, every loop is filled and held under pressure to prove there are no leaks. Slab and screed pipes are usually kept under pressure while the concrete goes down.

5. Cover and finish

A slab is poured, and a screed is laid and left to dry, which can take weeks before the floor covering goes on. Dry panels have nothing to dry: the floor covering goes over the panels, following the flooring guidance for floor heating.

6. Fill, balance and start up

The system is filled and the air bled out, the flow to each loop is set at the manifold, and the room thermostats are set up. The floor is warmed slowly the first time, which matters most for slabs, screeds and timber floors.

Who installs it

We supply HOYA Ondol Australia-wide, including South Australia, from Mount Gambier. Your builder, carpenter or flooring installer can lay the panels, and your own licensed hydronic plumber can connect the system. If you don’t have one, we can put you in touch with independent licensed hydronic installers who have installed HOYA Ondol floors in Sydney and Canberra, and who work in Adelaide and Mount Gambier. What builders, plumbers and installers need to know.

Licensed trades: manifold, heat pump and boiler connections must be made by a licensed plumber, and electrical work by a licensed electrician. In some states laying the heating pipe is also licensed plumbing work. Warranty requires licensed connections. This does not limit your rights under the Australian Consumer Law.

What does it cost to install?

There is no standard price per square metre, because each job is different. These are the things that set the price:

  • Floor area and number of rooms. More rooms means more loops and a larger manifold.
  • The heat source. A heat pump costs the most to buy and the least to run. An electric boiler costs the least to buy and more to run.
  • The method. In a new build, pipe in the slab adds little because the slab is being poured anyway. In an existing home, dry panels avoid breaking up the floor or waiting for a screed to dry.
  • Floor preparation. Levelling an uneven floor, or adding insulation under a suspended timber floor, adds to the job.
  • Controls. Room-by-room thermostats cost more than one central control, but save energy.
  • Trades. The plumber, electrician and floor layer each quote their part.

We quote the HOYA Ondol panels, pipe and manifold from your floor plan. For what goes into a quote and a worked example, see what hydronic floor heating costs to install and run.

The downsides, and when it is worth it

Hydronic heating is not the cheapest system to put in. These are the trade-offs to weigh up.

The downsides

  • It costs more to put in than a split system or a ducted system
  • Slab and screed floors are slow to respond, so they suit homes that are heated all day
  • It is a heating system. Cooling needs extra equipment such as fan coils
  • The manifold and heat source must be connected by a licensed plumber
  • Underfloor heating adds height to an existing floor, and the floor covering must suit floor heating

When it is usually worth it

  • You live somewhere with a long, cold winter
  • You are building, or replacing floors in a renovation, so the floor is open anyway
  • You want quiet, even warmth with no air blowing and no units on the walls
  • You have, or plan, solar panels and an air-to-water heat pump

What does it cost to run?

There is no single figure. Running cost depends on four things: the heat source and your energy tariff, how well the house is insulated, how many rooms you heat and how you control it. Room-by-room thermostats and a well-set heat pump make the biggest difference. Published research has found that the controls alone can change heating energy by around a quarter.

For a worked example with real prices, see what hydronic floor heating costs to install and run.

How much the floor weighs matters too. Independent studies have found that lighter floors without a thick screed warm up and respond faster. One modelling study found a thin dry system reached temperature about three times faster than a 65 mm screed. That helps in a home that is heated only when people are in it. These studies did not test HOYA Ondol panels.

Two white air-source heat pumps on a gravel bed beside a grey rendered house wall

Hydronic heating questions

A heating system that uses warm water instead of air. A boiler or heat pump heats the water, which is pumped through pipes to radiators or to pipes in the floor.

It costs more to install than split systems, it heats but does not cool on its own, slab systems are slow to respond, and it needs a licensed plumber for the connections. Underfloor heating in an existing home also adds some height to the floor.

It depends on the heat source, your tariff, insulation and controls. An air-to-water heat pump with room thermostats is usually the cheapest way to run it. For a home with solar panels, running the heat pump in the day helps further.

It is usually worth it in colder climates, in homes being built or renovated, and for people who want quiet, even warmth with nothing on the walls. In a mild climate or for a single room, a split system may be the better buy.

Yes, including older homes. Dry panels sit on the existing floor, so there is no concrete to break up and no screed to dry. Before you start, check the extra height at doorways and stairs (HOYA Ondol panels add 27.7 mm plus the floor covering), that the existing floor is level and sound, the insulation under a suspended timber floor, and where the manifold and heat source can go. Read about adding floor heating to an existing home.

Yes, with the right timber and installation. Read about timber floors over floor heating.

No. Hydronic heating circulates heated water through pipes from a heat pump or boiler. An oil-filled radiator is a sealed electric heater, so it costs the same to run as any other electric heater. Hydronic heating vs electric radiators.

For comfort and quiet, yes: a heated floor warms the room evenly with no air blowing. Ducted heating can also cool, if you need that from one system. Hydronic vs ducted vs split system heating.

Not on its own. Some heat pumps can chill water for fan coil units, but floors can only be cooled slightly before condensation becomes a risk.

More answers on our underfloor heating questions page.

Installation and warranty

The panels can be laid by a builder, carpenter or flooring installer, following HOYA Ondol’s installation instructions and the panel and pipe layout designed for your floor, working with your hydronic installer. Manifold, heat pump or boiler connections must be made by a licensed plumber, and electrical work by a licensed electrician. In some states, laying the heating pipe itself is also licensed plumbing work, so check with your installer. Warranty requires licensed connections. This does not limit your rights under the Australian Consumer Law.

Thinking about hydronic floor heating?

Send us your floor plan and we’ll quote the HOYA Ondol panels, pipe and manifold for your rooms.