HOYA Ondol panels go down over the floor you already have: a concrete slab, a sheet subfloor, timber floorboards or existing tiles. Nothing is poured and nothing has to dry before the floor covering goes on top.

Installer pressing heating pipe into HOYA Ondol panels laid over the existing floor of a stone cottage in Daylesford, Victoria

27.7 mm

Height before the floor covering

44–45 mm

Finished height with timber on top

3 mm

Flatness needed over 1 m

None

Drying time: nothing is poured

Why dry panels

Why dry panels suit a renovation

There are two other ways to get hydronic heat into a floor. Here is what each one costs you in an existing home.

Alternative 1

In-screed heating

The pipe is clipped down to the slab, then a wet sand-and-cement screed is poured over it.

What it costs you

  • About 70–110 mm of extra height, so doors, thresholds and stairs often need changes
  • About 120 kg/m² of screed for the floor to carry
  • Drying time before the floor covering can go down
  • A screed trade on top of your plumber and flooring installer

Alternative 2

In-slab heating

The pipe is tied to the reinforcing and cast into a new concrete slab.

What it costs you

  • New builds and extensions only: it can’t go into a floor that’s already built
  • The slab has to warm up before the room does, so it is slow to respond to the thermostat
  • The pipe can’t be reached or moved once the concrete is poured
  • Worth it mainly when you are pouring a new slab anyway

Compared

Height and weight of the heating layer

Height before the floor covering

HOYA Ondol: 27.7 mm

In-screed: about 70–110 mm

Weight per square metre

HOYA Ondol: 11.2–16.68 kg/m²

Wet screed: about 120 kg/m²

Bars drawn to scale against the upper figure for screed.

Why it matters

Less material over the pipe

A HOYA Ondol floor has no screed to pour, carry or dry. The panels weigh about a tenth of a wet screed and add less than half its height, so they suit floors that are already built, including heritage and older homes.

The floor covering goes down once the pipe passes its pressure test and, for timber, once the heating is commissioned.

The trade-off: a low-profile wet system adds less height, about 15 mm, but its compound has to dry, and HOYA Ondol uses more pipe per square metre. Compare every system on floor heating build-up heights.

Living area of a stone cottage in Daylesford, Victoria, with reflective foil being rolled out over the existing concrete floor before the HOYA Ondol panels go down

Existing floors

What the panels can go over

The panels sit on 1.7 mm HOYA Ondol reflective foil, laid straight over the existing floor. In Queens Park, Sydney, they went over a first-floor timber subfloor where a screed would have been too heavy. For older houses, see floor heating for heritage and period homes.

  • Concrete slab. Clean, dry and flat to within 3 mm over 1 m. Patch it or use self-levelling compound first if it isn’t.
  • Existing tiles. They can stay. The foil goes over the tiles and the panels sit on the foil, if the tiles are flat to the same 3 mm over 1 m.
  • Sheet subfloor. Sound, flat and firmly fixed. On a suspended floor, ask your builder about insulation underneath.
  • Timber floorboards. They can stay. The foil goes over the boards and the panels sit on the foil, if the boards are sound, firmly fixed and flat to the same 3 mm over 1 m. Fix any loose or squeaking boards first.
  • Old coverings. Carpet and floating floors come up first. The panels need a firm, flat base.

Before you start

Plan the height before you start

With timber on top, the finished floor is about 44–45 mm above the old one. Check these before you order.

Doors

Measure the gap under each door. Doors may need trimming to clear the new floor.

Thresholds

Plan the step or transition where the new floor meets an unheated room or outside door.

Stairs

A raised floor changes the top or bottom step. Ask your builder to check the step heights.

Kitchen

A higher floor leaves less room under benchtops. Check the dishwasher still fits.

Skirting boards

Skirtings usually come off and go back at the new floor level, over the edge gap.

Manifold and heat pump

Allow a cupboard or wall cabinet for the manifold and a spot outside for the heat pump.

Step by step

How a renovation goes

Send us your plans

We design the panel and pipe layout for the rooms you want heated, and quote the panels, pipe and manifold.

Prepare the floor

Lift any carpet or floating floor (tiles can stay), then clean the slab or subfloor and bring it to within 3 mm over 1 m.

Lay the foil and panels

A builder, carpenter or flooring installer lays the foil and panels to the layout plan, working with your hydronic installer.

Connect, test and commission

A licensed plumber connects the manifold and heat source and pressure-tests the pipe. For timber, the heating is commissioned before the boards go down.

Lay the floor covering

The covering goes down over the panels, to its maker’s instructions. Never glue it to the panels or fix anything into them.

Projects

HOYA Ondol in existing homes

Sunroom with white heating pipe laid in loops through the channels of the HOYA Ondol panels

Daylesford, Victoria

A stone cottage

A retrofit over the existing concrete floor: 67.2 m² heated with about 443 m of 16 mm PE-RT pipe, with a heat pump.

Large room in the O'Connor ACT renovation with white hydronic pipe loops laid in black HOYA Ondol panels and a coil of pipe on a dispenser

O’Connor, ACT

A 150 m² renovation

A renovation of about 150 m² in O’Connor, Canberra, with B- and C-Panels and a heat pump as the heat source.

Questions

Questions about renovations

Something else? Call us on 1300 137 407 or send us your plans.

Can I heat just some rooms?

Yes. Heat only the rooms you choose. Each room or area can be its own zone, with its own thermostat.

It depends on the size of the job and the heat source. There’s no drying time, and we estimate the timing with your layout and quote.

A heat pump or boiler, sized by your hydronic installer. See heat pumps.

Yes. Engineered oak floats over the panels. See timber floors over floor heating.

Keep reading

More about floor heating and timber floors

Bedroom with the timber floor cut away to show HOYA Ondol panels underneath

Timber floors

Timber floors over floor heating

Engineered oak floated over the panels, within its warranty limits.

Floor covering samples in timber-look and grey finishes, fanned out on a timber floor

Floor coverings

Which floor covering suits floor heating?

Timber, hybrid, laminate, tiles or carpet: what goes over the panels.

Flooring installer in a hi-vis shirt and knee pads laying a wide timber-look plank across a bare floor

For flooring installers

Laying timber over HOYA Ondol panels

Checks, the heating sequence and what to hand over.

Engineered timber boards laid over HOYA Ondol panels with the heating pipe in the channels

Owner care

Looking after a timber floor

Floor temperature, humidity, rugs and the seasons.

Installation and warranty

The panels can be laid by a builder, carpenter or flooring installer, following HOYA Ondol’s installation instructions and the panel and pipe layout designed for your floor, working with your hydronic installer. Manifold, heat pump or boiler connections must be made by a licensed plumber, and electrical work by a licensed electrician. In some states, laying the heating pipe itself is also licensed plumbing work, so check with your installer. Warranty requires licensed connections. This does not limit your rights under the Australian Consumer Law.

Renovating? Send us your plans

Leave your details and we’ll be in touch within one business day. Have a floor plan? Reply to our email with it and we’ll quote the panels, pipe and manifold.